Skip to product information
Elcometer 456 Separate Probes
$889.00 USD
Shipping calculated at checkout.
Elcometer 456 Interchangeable Probes – Precision, Range & Reliability
Industry-Leading Probe Solutions for Dry Film Thickness Measurement
The Elcometer 456 Probes are engineered to deliver highly accurate, repeatable, and temperature-stable measurements in even the most challenging inspection environments. Designed to work seamlessly with the Elcometer 456 gauge, our wide range of probes—from ferrous and non-ferrous to dual FNF and high-temperature models—ensures you have the right tool for any surface, curvature, or coating type.
✅ Key Features of Elcometer 456 Probes:
-
Fully Interchangeable Design
Swap probes on the fly without recalibrating your gauge—maximizing uptime and flexibility. -
Comprehensive Measurement Ranges
Get readings on 0–20 mils up to 0–1220 mils, cover virtually every coating thickness need. -
Specialist Probe Types
Standard, Mini, Right-Angle, Telescopic, Scan, Anodising, Waterproof, Soft Coating, Hi-Temp PINIP™ and more to tackle any geometry or environment. -
Patented Offset Calibration
Automatically compensates for probe cap wear, ensuring sustained accuracy over thousands of readings. -
Rugged & Reliable
Armoured cables, sealed housings and replaceable end-caps stand up to dust, water, impact and extreme temperatures (up to 250 °C). -
High-Speed Scan & Auto-Repeat Modes
Achieve 70+ readings per minute in spot-mode or over 140 readings/minute with scan probes—ideal for large-area inspections.
🔍 Probe Selection & Applications
- Ferrous (F) Probes – For non-magnetic coatings on steel substrates.
- Non-Ferrous (N) Probes – For non-conductive coatings on aluminium & other non-ferrous metals.
- Dual FNF Probes – Auto-detect substrate type and switch between ferrous/non-ferrous modes.
- Scan Probes – Rapidly scan large surfaces; view live average, min/max trends and store full data sets. Only works with Top Model Gauges
- Specialty Probes – Angled, telescopic, mini and soft-coating probes to reach restricted areas and delicate surfaces.
- High-Temperature PINIP™ Probes – Measure coatings on substrates up to 250 °C (480 °F) with integrated cap-over-foil calibration.
📦 What’s in the Box?
- Selected Elcometer 456 Probe (Scale & Type)
- Quick-Start Guide
🔧 Compatible With:
- Elcometer 456 Separate Gauge Models
- ElcoMaster® Data Management Software & Mobile App
- ISO, ASTM, SSPC, IMO, NAVSEA & Other International Standards
Equip your Elcometer 456 gauge with the perfect probe to achieve unmatched precision, speed and reliability—no matter the coating, substrate or environment.
- Refer to the Elcometer 456 data sheet for detailed probe ranges, accuracies and model-specific specifications.
Technical Specifications
| Scale 0.5: Range : 0-500μm (0-20mils) | |||||
| Accuracya | (±1-3% or ±0.1mil) | ||||
| Range | 0-500μm (0-20mils) | ||||
| Resolution | 0.1μm: 0-100μm (0.01mil: 0-5mils) 1μm: 100-500μm (0.1mil: 5-20mils) |
||||
| Certificate |
![]() |
||||
| Description | Part Number | Minimum Headroom | Minimum Sample Diameterb | Minimum Convex Surface Diameter | Minimum Concave Surface Radius |
| Ferrous (F) | |||||
| Straight Mini Probe Probe Length: 45mm (1.77”)c |
T456CFM3---A | 6mm (0.24”) | 3mm (0.12”) | 1.9mm (0.07") | 6.5mm (0.26") |
| Right Angle Mini Probe Probe Length: 45mm (1.77”)c |
T456CFM3R90A | 16mm (0.63”) | 3mm (0.12”) | 1.9mm (0.07") | 6.5mm (0.26") |
| 45° Angle Mini Probe Probe Length: 45mm (1.77”)c |
T456CFM3R45A | 16mm (0.63”) | 3mm (0.12”) | 1.9mm (0.07") | 6.5mm (0.26") |
| Straight Mini Probe Probe Length: 150mm (5.90”)c |
T456CFM3---C | 6mm (0.24”) | 3mm (0.12”) | 1.9mm (0.07") | 6.5mm (0.26") |
| Right Angle Mini Probe Probe Length: 150mm (5.90”)c |
T456CFM3R90C | 16mm (0.63”) | 3mm (0.12”) | 1.9mm (0.07") | 6.5mm (0.26") |
| 45° Angle Mini Probe Probe Length: 300mm (11.80”)c |
T456CFM3R45D | 18mm (0.71”) | 3mm (0.12”) | 1.9mm (0.07") | 6.5mm (0.26") |
| Right Angle Mini Probe Probe Length: 300mm (11.80”)c |
T456CFM3R90D | 16mm (0.63”) | 3mm (0.12”) | 1.9mm (0.07") | 6.5mm (0.26") |
| Non-Ferrous (N) | |||||
| Straight Mini Probe Probe Length: 45mm (1.77”)c |
T456CNM3---A | 6mm (0.24”) | 4mm (0.16”) | 6mm (0.24") | 8.5mm (0.33") |
| Right Angle Mini Probe Probe Length: 45mm (1.77”)c |
T456CNM3R90A | 16mm (0.63”) | 4mm (0.16”) | 6mm (0.24") | 8.5mm (0.33") |
| Straight Mini Probe Probe Length: 150mm (5.90”)c |
T456CNM3---C | 6mm (0.24”) | 4mm (0.16”) | 6mm (0.24") | 8.5mm (0.33") |
| Right Angle Mini Probe Probe Length: 150mm (5.90”)c |
T456CNM3R90C | 16mm (0.63”) | 4mm (0.16”) | 6mm (0.24") | 8.5mm (0.33") |
| Right Angle Mini Probe Probe Length: 400mm (15.70”)c |
T456CNM3R90E | 16mm (0.63”) | 4mm (0.16”) | 6mm (0.24") | 8.5mm (0.33") |
| Non-Ferrous - Graphite (N) | |||||
| Right Angle Mini Probe Probe Length: 45mm (1.77”)c |
T456CNMG3R90A | 16mm (0.63”) | 4mm (0.16”) | 6mm (0.24") | 8.5mm (0.33") |
| Right Angle Mini Probe Probe Length: 150mm (5.90”)c |
T456CNMG3R90C | 16mm (0.63”) | 4mm (0.16”) | 6mm (0.24") | 8.5mm (0.33") |
| Right Angle Mini Probe Probe Length: 400mm (15.70”)c |
T456CNMG3R90E | 16mm (0.63”) | 4mm (0.16”) | 6mm (0.24") | 8.5mm (0.33") |
| Scale 1: Range : 0-1500μm (0-60mils) | |||||
| Accuracyae | ±1-3% or ±2.5μm (±1-3% or ±0.1mil) | ||||
| Ranged | 0-1500μm (0-60mils) | ||||
| Resolution | 0.1μm: 0-100μm (0.01mil: 0-5mils) 1μm: 100-1500μm (0.1mil: 5-60mils) |
||||
| Certificate |
![]() |
||||
| Description | Part Number | Minimum Headroom | Minimum Sample Diameterb | Minimum Convex Surface Diameter | Minimum Concave Surface Radius |
| Ferrous (F) | |||||
| Straight Probe Probe Length: 45mm (1.77”)c |
T456CF1S | 85mm (3.35”) | 4mm (0.16”) | 4mm (0.16") | 25mm (0.98") |
| Straight Probe - sealed Probe Length: 45mm (1.77”)c |
T456CF1E | 85mm (3.35”) | 4mm (0.16”) | 4mm (0.16") | 25mm (0.98") |
| Scan Probe Probe Length: 45mm (1.77”)c |
T456CF1U | 86mm (3.38”) | 15mm (0.59”) | Flat Surface | Flat Surface |
| Scan Probe - armoured Probe Length: 45mm (1.77”)c |
T456CF1UARM | 140mm (5.51”) | 15mm (0.59”) | Flat Surface | Flat Surface |
| 90° Probe Probe Length: 45mm (1.77”)c |
T456CF1R | 28mm (1.10”) | 4mm (0.16”) | 4mm (0.16") | 25mm (0.98") |
| 90° Mini Probe Probe Length: 45mm (1.77”)c |
T456CFM5R90A | 16mm (0.63”) | 4mm (0.16”) | 3mm (0.12") | 6.5mm (0.26") |
| 90° Mini Probe - sealed Probe Length: 45mm (1.77”)c |
T456CFME5R90A | 16mm (0.63”) | 4mm (0.16”) | 3mm (0.12") | 6.5mm (0.26") |
| 90° Mini Probe - sealed, 2m cable Probe Length: 45mm (1.77”)c |
T456CFME5R90A-2 | 16mm (0.63”) | 4mm (0.16”) | 3mm (0.12") | 6.5mm (0.26") |
| PINIP™ Integral Probe | T456CF1P | 170mm (6.69”) | 4mm (0.16”) | 4mm (0.16") | 60mm (2.36") |
| Non-Ferrous (N) | |||||
| Straight Probe Probe Length: 45mm (1.77”)c |
T456CN1S | 85mm (3.35”) | 4mm (0.16”) | 10mm (0.39") | 10mm (0.39") |
| 90° Probe Probe Length: 45mm (1.77”)c |
T456CN1R | 28mm (1.10”) | 4mm (0.16”) | 10mm (0.39") | 14mm (0.55") |
| Mini 90° Probe Probe Length: 45mm (1.77”)c |
T456CNM5R90A | 16mm (0.63”) | 4mm (0.16”) | 10mm (0.39") | 8.5mm (0.33") |
| Mini 90°Probe Probe Length: 150mm (5.90”)c |
T456CNM5R90C | 16mm (0.63”) | 4mm (0.16”) | 10mm (0.39") | 8.5mm (0.33") |
| Mini 90° Probe Probe Length: 400mm (15.7”)c |
T456CNM5R90E | 16mm (0.63”) | 4mm (0.16”) | 10mm (0.39") | 8.5mm (0.33") |
| Anodiser Probe Probe Length: 45mm (1.77”)c |
T456CN1AS | 100mm (3.94”) | 4mm (0.16”) | 10mm (0.39") | 14mm (0.55") |
| PINIP™ Integral Probe | T456CN1P | 180mm (7.09”) | 4mm (0.16”) | 10mm (0.39") | 50mm (1.97") |
| Ferrous & Non-Ferrous (FNF) | |||||
| Straight Probe Probe Length: 45mm (1.77”)c |
T456CFNF1S | 88mm (3.46”) | F: 4mm (0.16”), N: 6mm (0.24”) | F: 4mm (0.16") N: 26mm (1.02") |
12.5mm (0.49") |
| Straight Probe - armoured cable Probe Length: 45mm (1.77”)c |
T456CFNF1ARM | 185mm (7.28") | F: 4mm (0.16”), N: 6mm (0.24”) | F: 4mm (0.16") N: 26mm (1.02") |
12.5mm (0.49") |
| Scan Probe Probe Length: 45mm (1.77”)c |
T456CFNF1U | 89mm (3.50”) | 15mm (0.59”) | Flat Surface | Flat Surface |
| Right Angle Probe Probe Length: 45mm (1.77”)c |
T456CFNF1R | 38mm (1.50”) | F: 4mm (0.16”), N: 6mm (0.24”) | F: 4mm (0.16") N: 26mm (1.02") |
12.5mm (0.49") |
| PINIP™ Integral Probe | T456CFNF1P | 180mm (7.09”) | F: 4mm (0.16”), N: 6mm (0.24”) | F: 4mm (0.16") N: 26mm (1.02") |
65mm (2.56") |
| Scale 2: Range : 0-5mm (0-200mils) | |||||
| Accuracyae | ±1-3% or ±20μm (±1-3% or ±1.0mil) | ||||
| Ranged | 0-5mm (0-200mils) | ||||
| Resolution | 1μm: 0-1mm (0.1mil: 0-50mils) 10μm: 1-5mm (1.0mil: 50-200mils) |
||||
| Certificate |
![]() |
||||
| Description | Part Number | Minimum Headroom | Minimum Sample Diameterb | Minimum Convex Surface Diameter | Minimum Concave Surface Radius |
| Ferrous (F) | |||||
| Straight Probe Probe Length: 45mm (1.77”)c |
T456CF2S | 89mm (3.50”) | 8mm (0.32”) | 4mm (0.16") | 25mm (0.98") |
| Scan Probe Probe Length: 45mm (1.77”)c |
T456CF2U | 90mm (3.54”) | 15mm (0.59”) | Flat Surface | Flat Surface |
| 90° Probe Probe Length: 45mm (1.77”)c |
T456CF2R | 32mm (1.26”) | 8mm (0.32”) | 4mm (0.16") | 25mm (0.98") |
| Straight Probe - armoured cable Probe Length: 45mm (1.77”)c |
T456CF2ARM | 138mm (5.43”) | 8mm (0.32”) | 4mm (0.16") | 25mm (0.98") |
| Telescopic Probe Probe Length: 56-122cm (22-48”)c |
T456CF2T | 36mm (1.42”) | 8mm (0.32”) | 4mm (0.16") | 25mm (0.98") |
| Soft Coating Probe Probe Length: 45mm (1.77”)c |
T456CF2B | 89mm (3.50”) | 8mm (0.32”) | Flat Surface | Flat Surface |
| Waterproof Probe - 1m (3’) cable Probe Length: 45mm (1.77”)c |
T456CF2SW | 138mm (5.43”) | 8mm (0.32”) | 4mm (0.16") | 40mm (1.98") |
| Waterproof Probe - 5m (15’) cable Probe Length: 45mm (1.77”)c |
T456CF2SW-5 | 138mm (5.43”) | 8mm (0.32”) | 4mm (0.16") | 40mm (1.98") |
| Waterproof Probe - 15m (45’) cable Probe Length: 45mm (1.77”)c |
T456CF2SW-15 | 138mm (5.43”) | 8mm (0.32”) | 4mm (0.16") | 40mm (1.98") |
| Waterproof Probe - 30m (98’) cable Probe Length: 45mm (1.77”)c |
T456CF2SW-30 | 138mm (5.43”) | 8mm (0.32”) | 4mm (0.16") | 40mm (1.98") |
| Waterproof Probe - 50m (164’) cable Probe Length: 45mm (1.77”)c |
T456CF2SW-50 | 138mm (5.43”) | 8mm (0.32”) | 4mm (0.16") | 40mm (1.98") |
| Waterproof Probe - 75m (250’) cable Probe Length: 45mm (1.77”)c |
T456CF2SW-75 | 138mm (5.43”) | 8mm (0.32”) | 4mm (0.16") | 40mm (1.98") |
| PINIP™ Integral Probe | T456CF2P | 174mm (6.85”) | 8mm (0.32”) | 4mm (0.16") | 60mm (2.36") |
| Hi-Temperature PINIP™ | T456CF2PHT | 174mm (6.85”) | 8mm (0.32”) | 4mm (0.16") | 60mm (2.36") |
| Non-Ferrous (N) | |||||
| Straight Probe Probe Length: 45mm (1.77”)c |
T456CN2S | 88mm (3.46”) | 14mm (0.55”) | 100mm (3.97") | 150mm (5.90") |
| PINIP™ Integral Probe | T456CN2P | 185mm (7.28") | 14mm (0.55”) | 100mm (3.97") | 150mm (5.90") |
| Scale 3: Range : 0-13mm (0-500mils) | |||||
| Accuracya | ±1-3% or ±50μm (±1-3% or ±2.0mils) | ||||
| Ranged | 0-13mm (0-500mils) | ||||
| Resolution | 1μm: 0-2mm (0.1mil: 0-100mils) 10μm: 2-13mm (1.0mil: 100-500mils) |
||||
| Certificate |
![]() |
||||
| Description | Part Number | Minimum Headroom | Minimum Sample Diameterb | Minimum Convex Surface Diameter | Minimum Concave Surface Radius |
| Ferrous (F) | |||||
| Straight Probe Probe Length: 45mm (1.77”)c |
T456CF3S | 102mm (4.02”) | 14mm (0.55”) | 15mm (0.59") | 40mm (1.98") |
| PINIP™ Integral Probe | T456CF3P | 184mm (7.24”) | 14mm (0.55”) | 15mm (0.59") | 45mm (1.77") |
| Non-Ferrous (N) | |||||
| Straight Probe Probe Length: 45mm (1.77”)c |
T456CN3S | 170mm (6.69”) | 35mm (1.38”) | Flat Surface | Flat Surface |
| Scale FM7: Range: 0.60-3.8mm (25-150mils) | |||||
| Accuracya | ±7.5% or ±114μm (±7.5% or ±4.5mils) | ||||
| Ranged | 0.60-3.8mm (25-150mils) | ||||
| Resolution | 1μm: 0-1mm (0.1mil: 0-139.3mils) 10μm: 1-3.8mm (1.0mil: 39.4-150mils) |
||||
| Certificate |
![]() |
||||
| Description | Part Number | Minimum Headroom | Minimum Sample Diameterb | Minimum Convex Surface Diameter | Minimum Concave Surface Radius |
| Ferrous (F) | |||||
| 45° Angle Mini Probe Probe Length: 45mm (1.77”)c |
T456CFM7R45A | 20mm (0.79”) | 6.5 mm (0.26’’) | - | - |
| Scale 6: Range : F: 0-25mm (F: 0-980mils) N: 0-30mm (N: 0-1200mils) |
|||||
| Accuracya | ±1-3% or ±100μm (±1-3% or ±4.0mils) | ||||
| Ranged | F: 0-25mm (F: 0-980mils) N: 0-30mm (N: 0-1200mils) |
||||
| Resolution | 10μm: 0-2mm (1mil: 0-100mils) 100μm: 2-30mm (10mils: 100-1200mils) |
||||
| Certificate |
![]() |
||||
| Description | Part Number | Minimum Headroom | Minimum Sample Diameterb | Minimum Convex Surface Diameter | Minimum Concave Surface Radius |
| Ferrous (F) | |||||
| Straight Probe Probe Length: 45mm (1.77”)c |
T456CF6S | 150mm (5.90”) | 51 x 51mm2 (2.17 x 2.17 inch2) | 35mm (1.40") | 170mm (6.70") |
| Straight Probe - armoured cable Probe Length: 45mm (1.77”)c |
T456CF6ARM | 190mm (7.48”) | 51 x 51mm2 (2.17 x 2.17 inch2) | 35mm (1.40") | 170mm (6.70") |
| Non-Ferrous (N) | |||||
| Straight Probe Probe Length: 45mm (1.77”)c |
T456CN6S | 160mm (6.30”) | 58mm (2.29”) | Flat Surface | Flat Surface |
| Straight Probe - armoured cable Probe Length: 45mm (1.77”)c |
T456CN6ARM | 200mm (7.87") | 58mm (2.29”) | Flat Surface | Flat Surface |
| Scale 7: Range : 0-31mm (0-1220mils) | |||||
| Accuracya | ±1-3% or ±100μm (±1-3% or ±4.0mils) | ||||
| Ranged | 0-31mm (0-1220mils) | ||||
| Resolution | 10μm: 0-2mm (1.0mil: 0-100mils) 100μm: 2-31mm (10mils: 100-1220mils) |
||||
| Certificate |
![]() |
||||
| Description | Part Number | Minimum Headroom | Minimum Sample Diameterb | Minimum Convex Surface Diameter | Minimum Concave Surface Radius |
| Ferrous (F) | |||||
| Straight Probe armoured cable Probe Length: 45mm (1.77”)c |
T456CF7ARM | 200mm (7.87") | 55 x 55mm2 (2.17 x 2.17 inch2) | 40mm (1.58") | 170mm (6.70") |